Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine

Product Details
Customization: Available
After-sales Service: Provided
Warranty: One-Year
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
T/T PayPal ApplePay GooglePay visa mastercard american express discover
JCB diners club PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

R&D Capabilities
The supplier has 6 R&D engineers, you can check the Audit Report for more information
100% Finished Products Inspection
The supplier inspects 100% of finished products.
ODM Services
The supplier provides ODM services
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (24)
  • Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
  • Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
  • Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
  • Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
  • Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
  • Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
Find Similar Products
  • Overview
  • Product Description
  • PRODUCT FUNCTION
  • Technical Parameters
  • PRODUCT APPLICATION
  • Company Profile
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
NRYH600
Accuracy Grade
1
Load Way
Electronic Load
Display
Digital
Control
Computer Control
Weight
21kg
Power Source
AC 220V (1±10%)
Temperature Range
0 - 125 C
Temperature Measurement Error
+ 0.5 C
AC Experimental Voltag
500 ~ 2200V Continuous Adjustable ,Frequency 50Hz
DC Test Voltage
0 ~ 500V Continuous Adjustable
Power Consumption
100W
Transport Package
Wooden Box with Foam Inside
Specification
420mm*380mm*385mm
Trademark
Refine On
Origin
China
HS Code
9030899090
Production Capacity
100 Set Per Week

Packaging & Delivery

Package Size
62.00cm * 48.00cm * 48.00cm
Package Gross Weight
30.000kg

Product Description

Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
Product Description
Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
PRODUCT FUNCTION
NRYH600 Insulating Oil Dielectric Loss And Resistivity Tester
FUNCTION
1. High automation, heating, measuring dielectric loss, measuring resistivity can be completed once.
2. The three electrode type structure with an GB/T5654-2007 standard, inter electrode spacing 2mm, can eliminate stray capacitance and leakage effect on the dielectric loss test results.
3. Instrument using medium frequency induction heating, PID temperature control algorithm. This heating mode has the advantages of non-contact, oil cup and heating body, uniform heating speed, convenient control, the temperature control in temperature within the preset range error.
4. Using advanced DSP and FFT technology to ensure data stability, accurate and reliable.
5. Internal standard capacitor for the SF6 charging three pole capacitor, dielectric loss and capacitance of the capacitor is not affected by ambient temperature, humidity, etc., so that the accuracy of the instrument after a long time to use is still guaranteed.
6. Large screen color touch screen, man-machine dialogue convenient, concise operation, clear.
7. With the lid off the high voltage, high voltage electrode cup short reminder, eliminate safety hazards, to ensure the normal operation of the safety of operating personnel and equipment.
8. With real-time clock, test date, time can be saved with the test results, display, print; equipment can display the ambient temperature, real-time detection of the test environment.
9. Automatic storage measurement data, can store 100 sets of measurement data.
10. Calibration function of empty electrode cup. The capacitance and dielectric loss factor of the empty electrode cup are measured to judge the cleaning and assembling condition of the empty electrode cup. The calibration data are saved automatically to facilitate the accurate calculation of relative capacitance and DC resistivity.
Technical Parameters
Measuring Range
Capacitance: 5pF-200pF
Relative Capacitance: 1.000-30.000
Dielectric Loss Factor: 0.00001-100
DC Resistivity: 2.5 MΩm-20 TΩm
Measurement Accuracy
Capacitance: ±(1% reading +0.5pF)
Relative Capacitance: ± 1%
Dielectric Loss Factor: ±(1% reading +0.0001)
Direct Current Resistivity: ± 10% reading
Resolution
Capacitance: 0.01pF
Relative Capacity: 0.001
Dielectric Loss Factor: 0.00001
Temperature Range
0 ~ 125℃
Temperature Measurement Error
± 0.5℃
AC Experimental Voltage
500 ~ 2200V continuous adjustable, frequency 50Hz
DC Test Voltage
0 ~ 500V continuous adjustable
Power Consumption
100W
Dimensions
420mm380mm385mm
Total Weight
21Kg
PRODUCT APPLICATION
Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
Company Profile
ABOUT US
Refine On (Hebei) Electric Power Technology Co., Ltd. is located in the Mancheng High-tech Development Zone, Baoding. It is fully committed to the high-tech field of power system automation, specializing in the research and development of a series of products such as power system marketing measurement, operation and maintenance high-voltage testing, distribution network testing, power consumption inspection, and tools and meters. It is a technology-oriented enterprise integrating R&D, production, sales and service. The company provides instruments, meters and testing equipment related to power generation, transmission, transformation, distribution and sales. Provide sales of complete sets of instruments and equipment required for installation (repair, testing) of Grade one, Grade Two, Grade Three and Grade Four.
The company is equipped with various production, testing and inspection facilities, has a sound management system, and strictly adheres to the GB/T19001-2016 quality management system standard for production and operation. A number of high-tech instruments and equipment that meet the on-site requirements have been developed. At present, the products have been widely applied in multiple fields such as power, railway, mining, petroleum and chemical engineering.
The company has obtained the Quality management System certification certificate, 2 invention patents, 10 utility model patents and 20 software Copyrights. And it has established long-term and close cooperative relations with units such as Beijing Institute of Metrology, Beijing Electric Power Research Institute, and Hebei Institute of Metrology.
Our main products include insulating oil tester series, insulating resistance tester, power quality analyzer, circuit breaker, relay protection tester, high-voltage generator, high-voltage capacitor, test transformer, transformer test series, etc.
Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
Certifications
Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
Packaging & Shipping
Comprehensive Insulating Oil Dielectric Loss and Resistivity Universal Testing Machine
FAQ
FAQ
1. Insulating Oil Tester Series
1.1 What is the main function of the Insulating Oil Dielectric Strength Tester (80kv/100kv)?
Tests insulating oil's dielectric strength to detect impurities, moisture, or aging, ensuring safe operation of transformers and circuit breakers.
1.2 How often should the Insulating Oil Dielectric Strength Tester be calibrated?
At least once a year; shorten intervals for frequent use, harsh environments, or post-maintenance.
1.3 What is the difference between the Closed Cup Flash Point Automatic Tester and the Open Cup Flash Point Automatic Tester?
• Closed Cup: Tests in sealed containers; for low-flash oils (e.g., diesel) and sealed power equipment.
• Open Cup: Tests in open containers; for high-flash oils (e.g., insulating oil) and air-exposed scenarios.
2. Transformer Test Series
2.1 What can the Transformer Capacity Tester detect?
Detects transformer's actual capacity, no-load/load loss, no-load current, and impedance voltage; judges compliance and faults.
2.2 How to use the Transformer Tap Changer Tester?
1. Connect test lines to tap changer terminals per manual.
2. Power on, select test mode (e.g., resistance test).
3. View results; disconnect and power off after. (Note: De-energize and ground transformer first.)
2.3 What is the purpose of the Transformer Winding Deformation Tester?
Detects winding deformation (axial displacement, short circuits) from short-circuits or vibration; enables early maintenance to avoid accidents.
FAQ
3. Circuit Breaker Test Instruments
3.1 What are the differences between the Single-Chip Microcomputer and Industrial Computer Circuit Breaker Characteristic Testers?
• Industrial Computer: Stronger data processing, more tests (e.g., dynamic resistance), touch interface, and computer data communication.
• Single-Chip: Simple structure, low cost; for basic characteristic tests.
3.2 How to judge whether the Circuit Breaker Characteristic Tester is working normally?
1. Check power and indicator lights.
2. Run self-test; test a standard circuit breaker.
3. Confirm results are within allowable error. Stop use if self-test fails or errors are large.
4. Cable Fault Test Instruments
4.1 What types of cable faults can the Multiple Pulse Cable Fault Tester detect?
Detects low-resistance (short circuits), high-resistance (leakage), and open-circuit faults; locates faults via pulse reflection.
4.2 How to improve the accuracy of the Cable Fault Location Tester?
• Ensure correct, firm test line connections.
• Select proper test mode/parameters for fault type.
• Eliminate environmental interference; keep site clean/dry.
• Calibrate regularly.
• Test multiple times for complex faults; analyze results comprehensively.
5. Insulation Resistance Tester
5.1 What is the application scope of the High-Voltage Insulation Resistance Tester?
Tests insulation of high-voltage equipment (transformers, generators, cables, etc.); checks for moisture, dirt, or aging to support commissioning and maintenance.
5.2 How to (complete based on full content; core steps?
Store in dry environment, avoid impact; clean terminals before use; calibrate regularly to maintain accuracy.)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now